AQ Guard

Description of item
Compact ambient air quality monitor. Featuring highly precise fine dust measurement, CO2 and TVOC, Palas® Air Quality and Infection Risk Index.

SKU: AQ Guard Categories: ,

Features And Benefits
• Technology based on the type approved Fidas ® 200 series (EN16450 and MCERTS); simultaneous measurement of Cn, PM1, PM2.5, PM4, PM10.
• Computation of air quality index based on measurements of particulates, CO2 and VOC.
• High accuracy due to advanced algorithms.
• Long term stable due to self calibration for measurement of flow rate, particulates, and gaseous pollutants.
• 2 years operation without calibration.
• Operates on AC, DC, or power-over-Ethernet.

Applications
• Industry:
                  – Production processes
                  – Bulk material handling (mixing, discharge, storage, packaging etc)
                  – Fenceline Monitoring
• Construction sites: Roads, railroads, demolition sites.
• Buildings: Schools, kindergartens, hospitals, hotels, offices, public service buildings.
• Residential buildings near construction sites or other polluted areas.
• Public transportation: Airports, train stations, tramway underground stations, cruise ships, passenger cabin, e.g. in tram, train.

MODELAQ Guard
InterfacesUSB, Ethernetm Wi-Fi, optional: UMTS
Measurement range (size)0.175 - 20µm
Size channels64 (32/decade)
Measuring principleSingle particle optical light scattering with evaluation of signal duration and shape, advanced mass conversion algorithm
Measurement range (number Cn)0 - 20,000 particles/cm³
Volume flow1.0 l/min ⩠ 0.06 m³ /h
Data acquisitionDigital, 22MHz processor, 256 raw data channels
Light sourceLong term stable LED
Power consumption< 15 W
User interfaceTouchscreen 800 x 480 Pixels, 5" (12.7cm)
Dimensions280mm x 175mm x 140mm (W x H x D)
Weight2.4 kg
Operating systemWindows 10 loT Enterprise
Data logger storage10 GB
SoftwarePDAnalyze
Response time1 s
Aerosol conditioningThermal with compact IADS
Measurement range (mass)0 - 20,000 µg/m³
Reported dataPM1, PM2.5, PM4, PM10, TSP, C , particle size distribution, pressure, temperature, relative humidity, CO2, TVOC, Air Quality Index
Installation conditions-20 - +50ºC
Linearity0.95 - 1.05 (measured against EN16450 certified Fidas® 200)
AccuracyR2 > 0.98 for PM2.5 and R2 > 0.94 for PM10 versus EN16450-certified Fidas®200 (15 min average each)